Panneau 6 circuits 120/240 volts 1 phase Square D

QO6L100S

QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 100 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 6 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 8 AWG to 1 AWG copper or aluminum wire. The load center is 12.56 inches tall, 8.90 inches wide and 3.74 inches deep. The load center is CSA certified.

Informations supplémentaires :

QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 100 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 6 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 8 AWG to 1 AWG copper or aluminum wire. The load center is 12.56 inches tall, 8.90 inches wide and 3.74 inches deep. The load center is CSA certified.

Nombre maximum de disjoncteurs tandem0Nombre de phases1 phase
Courant nominal maximum de court-circuit10 kACourant nominal100 A
Hauteur12.56 in (319 mm)Tension nominale120/240 V AC
Garantie18 moisTempérature de l'air ambiant pour le fonctionnement23 °F (-5 °C) || 104 °F (40 °C)
Configuration du câblage3-WireProfondeur3.74 in (95 mm)
Nombre maximum de circuits unipolaires6Nombre d'espaces6
Largeur8.90 in (226 mm)Matériau du jeu de barresAluminium étamé: jeu de barres
Type (fr)Centre de distributionDirective rohs de l'ueConforme
Connexion électriqueCossesType de couvertureCouverture de surface
Certifications / normesCULusFinition de surfaceÉmail cuit gris
Type de panneau de dérivationFixed Mains (lugs)Barre de mise à la terreGrounding bar (ordered separately)
Couple de serrageMain lugs 50 lb.in, AWG 8, aluminum/copper || Main lugs 50 lb.in, AWG 6...AWG 1/0, aluminum/copperÉvaluation du boîtierNEMA 1 intérieur
Sans mercureOuiSans métaux lourds toxiquesOui
Echa sans sepOuiStatut vert premiumProduit Vert Premium
Nom commercialQOMarqueSquare D
Matériau du boîtierTôle d'acier soudée